telit: tests: fix LN920 current bands configuration

Fix LN920 current bands test configuration by setting
modem_has_hex_format_4g_bands to TRUE.

The current wrong setting does not cause the test failure since the modem
supports also extended settings and function telit_get_ext_4g_mm_bands
considers both standard and extended bands as hex without checking
the flag, since decimal format for extended bands is not supported.

Signed-off-by: Daniele Palmas <dnlplm@gmail.com>
This commit is contained in:
Daniele Palmas
2026-07-07 10:55:13 -05:00
committed by Dan Williams
parent 545b183934
commit e292401beb
@@ -292,7 +292,7 @@ static BndResponseTest current_band_mapping_tests [] = {
},
/* 4G ext band settings: devices such as LN920 */
{
"#BND: 0,0,1003100185A,42", {FALSE, TRUE, TRUE, FALSE, FALSE, TRUE}, 13,
"#BND: 0,0,1003100185A,42", {FALSE, TRUE, TRUE, FALSE, TRUE, TRUE}, 13,
{ MM_MODEM_BAND_UTRAN_1,
MM_MODEM_BAND_EUTRAN_2,
MM_MODEM_BAND_EUTRAN_4,